Call Us! 0300-4564645 | Email:alliedengineering22@gmail.com

M880M

M880M

  • Electronic governor
  • Mechanically welded chassis with antivibration suspension
  • Main line circuit breaker
  • Radiator for wiring temperature of 48/50°C max with mechanical fan
  • Protective grille for fan and rotating parts
  • 9 dB(A) silencer supplied separately
  • Charger DC starting battery with electrolyte
  • 12 V charge alternator and starter
  • Delivered with oil and coolant -30°C
  • Manual for use and installation
SPECIFICATIONS

M880M

Engine Model

Alternator type

Performance class

D2862 LE 221

ECO43 1S4 A

G3

DIMENSIONS COMPACT VERSION

Length (mm)

Width (mm)

Height (mm)

Dry weight (kg)

Tank capacity (L)

4300

1700

2120

6340

700

GENERAL CHARACTERISTICS

Frequency (Hz)

Reference voltage (V)

Max power ESP (kVA)

Max power ESP (kWe)

Max power PRP (kVA)

Max power PRP (kWe)

Intensity (A)

Standard Control Panel

Optional control panel

50

400/230

880

704

800

640

DSE 7110

DSE 7210

POWER

Voltage

415/240

400/230

380/220

240 TRI

230 TRI

220 TRI

200/115

kWe ESP

704

704

704

704

704

704

704

kVa ESP

880

880

880

880

880

880

880

kWe PRP

640

640

640

640

640

640

640

kVa PRP

800

800

800

800

800

800

800

Standby Amps

1043

1082

1139

3125

3260

3409

3750

ENGINE SPECIFICATIONS

GENERAL ENGINE DATA

Engine model

Cylinder arrangement

Displacement (C.I.)

Bore (mm) x Stroke (mm)

Compression ratio

Speed (RPM)

Pistons speed (m/s)

Maximum stand-by power at rated RPM (kW)

Frequency regulation (%)

BMEP (bar)

Governor type

MAN D2862 LE221, 4-temps, Turbo , Air/Air DC 12 X

L

12.42

128 x 157

17:1

1500

7.85

728

+/- 0.5%

25.4

Electronic

COOLING SYSTEMS

Radiator & Engine capacity (L)

Max water temperature (°C)

Outlet water temperature (°C)

Fan power (kW)

Fan air flow w/o restriction (m3/s)

Available restriction on air flow (mm EC)

Type of coolant

Thermostat (°C)

117

100

40

30

9

20

MAN

82

EMISSIONS

Emission PM (g/kW.h)

Emission CO (g/kW.h)

Emission HCNOx (g/kWh)

Emission HC (g/kW.h)

N/A

N/A

N/A

N/A

EXHAUST

Exhaust gas temperature (°C)

Exhaust gas flow (kg/h)

Max. exhaust back pressure (mm EC)

606

2709

750

FUEL

Consumption @ 110% load (L/h)

Consumption @ 100% load (L/h)

Consumption @ 75% load (L/h)

Consumption @ 50% load (L/h)

Maximum fuel pump flow (L/h)

117

162

124

88

N/A

OIL

Oil capacity (L)

Min. oil pressure (bar)

Max. oil pressure (bar)

Oil consumption 100% load (g/h)

Carter oil capacity (L)

90

2.5

6

670

N/A

HEAT BALANCE

Heat rejection to exhaust (kW)

Radiated heat to ambiant (kW)

Haet rejection to coolant (kW)

457

280

270

AIR INTAKE

Max. intake restriction (mm EC)

Intake air flow (m³)

870

2348