Call Us: 0300-4564645 | Email: alliedengineering22@gmail.com

S710M

S710M

  • Electronic governor
  • Mechanically welded chassis with antivibration suspension
  • Main line circuit breaker
  • Radiator for wiring temperature of 48/50°C max with mechanical fan
  • Protective grille for fan and rotating parts
  • 9 dB(A) silencer supplied separately
  • Charger DC starting battery with electrolyte
  • 24 V charge alternator and starter
  • Delivered with oil and coolant -30°C
  • Manual for use and installation
SPECIFICATIONS

S710M

Engine Model

Alternator type

Performance class

DC16 093A

ECO40 2L4B

G2

DIMENSIONS COMPACT VERSION

Length (mm)

Width (mm)

Height (mm)

Dry weight (kg)

Tank capacity (L)

3474

1500

1910

4851

1000

GENERAL CHARACTERISTICS

Frequency (Hz)

Reference voltage (V)

Max power ESP (kVA)

Max power ESP (kWe)

Max power PRP (kVA)

Max power PRP (kWe)

Intensity (A)

Standard Control Panel

Optional control panel

50

400/230

721

577

650

520

923

DSE 7110

DSE 7210

POWER

Voltage

415/240

400/230

380/220

kWe ESP

577

577

577

kVa ESP

721

721

721

kWe PRP

520

520

520

kVa PRP

650

650

650

Standby Amps

1003

1041

1096

ENGINE SPECIFICATIONS

GENERAL ENGINE DATA

Engine model

Cylinder arrangement

Displacement (C.I.)

Bore (mm) x Stroke (mm)

Compression ratio

Speed (RPM)

Pistons speed (m/s)

Maximum stand-by power at rated RPM (kW)

Frequency regulation (%)

BMEP (bar)

Governor type

SCANIA Sweden DC16 093 A,4-temps, Turbo , Air/Air DC 8

V

16.4

130 x 154

16.7:1

1500

8.0

680

+/- 0.5%

N/A

Electronic

COOLING SYSTEMS

Radiator & Engine capacity (L)

Max water temperature (°C)

Outlet water temperature (°C)

Fan power (kW)

Fan air flow w/o restriction (kg/s)

Available restriction on air flow (pa)

Type of coolant

Thermostat (°C)

68

90

95

25

20

260

cool Guard

82-87

EMISSIONS

Emission PM (g/kW.h)

Emission CO (g/kW.h)

Emission HCNOx (g/kWh)

Emission HC (g/kW.h)

N/A

N/A

N/A

N/A

EXHAUST

Exhaust gas temperature (°C)

Exhaust gas flow (kg/m)

Max. exhaust back pressure (mm EC)

565

41

750

FUEL

Consumption @ 110% load (L/h)

Consumption @ 100% load (L/h)

Consumption @ 75% load (L/h)

Consumption @ 50% load (L/h)

156

141

104

70

OIL

Oil capacity (L)

Min. oil pressure (bar)

Max. oil pressure (bar)

Oil consumption 100% load (g/kWH)

Carter oil capacity (L)

40-48

.7

6

<0.2

N/A

HEAT BALANCE

Heat rejection to exhaust (kW)

Radiated heat to ambiant (kW)

Haet rejection to coolant (kW)

419

57

232

AIR INTAKE

Max. intake restriction (mm EC)

Intake air flow (kg/m)

625

39