Call Us! 0300-4564645 | Email:alliedengineering22@gmail.com
Home
Product
Generator
JD110M
JD130M
JD165M
JD220M
JD22M
JD275M
JD330M
JD33M
JD375M
JD440M
JD44M
JD550M
JD66M
JD88M
M1027M
M440M
M880M
MAN-256kVA
MAN-436kVA
MAN-52kVA
MAN-531kVA
MAN-61kVA
MAN-652kVA
MAN-79kVA
MAN-85kVA
S275M-250kVa
S330M-300kVA
S366M-330kVA
S375M-350kVA
S450M-400kVA
S500M-450kVA
S550M-500kVA
S710M-650kVA
S770M-710kVA
General Order Supplier
Solar Panel
About Us
X
S375M
S375M
Electronic governor
Mechanically welded chassis with antivibration suspension
Main line circuit breaker
Radiator for wiring temperature of 48/50°C max with mechanical fan
Protective grille for fan and rotating parts
9 dB(A) silencer supplied separately
Charger DC starting battery with electrolyte
24 V charge alternator and starter
Delivered with oil and coolant -30°C
Manual for use and installation
SPECIFICATIONS
S375M
Engine Model
Alternator type
Performance class
DC13 072A
ECO38 3L4A
G2
DIMENSIONS COMPACT VERSION
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
3000
1220
1527
3570
500
GENERAL CHARACTERISTICS
Frequency (Hz)
Reference voltage (V)
Max power ESP (kVA)
Max power ESP (kWe)
Max power PRP (kVA)
Max power PRP (kWe)
Intensity (A)
Standard Control Panel
Optional control panel
50
400/230
388
310
350
280
541
DSE 4510
DSE 6610
POWER
Voltage
415/240
400/230
380/220
kWe ESP
300
300
300
kVa ESP
375
375
375
kWe PRP
280
280
280
kVa PRP
350
350
350
Standby Amps
521
541
570
ENGINE SPECIFICATIONS
GENERAL ENGINE DATA
Engine model
Cylinder arrangement
Displacement (C.I.)
Bore (mm) x Stroke (mm)
Compression ratio
Speed (RPM)
Pistons speed (m/s)
Maximum stand-by power at rated RPM (kW)
Frequency regulation (%)
BMEP (bar)
Governor type
SCANIA DC13 072 A , 4-temps, Turbo , Air/Air DC 6 X
L
12.7
130 x 160
16.3:1
1500
8.0
356
+/- 0.5%
N/A
Electronic
COOLING SYSTEMS
Radiator & Engine capacity (L)
Max water temperature (°C)
Outlet water temperature (°C)
Fan power (kW)
Fan air flow w/o restriction (kg/s)
Available restriction on air flow (mm pa)
Type of coolant
Thermostat (°C)
37
95
80
6
6.1
20
SCANIA
80-87
EMISSIONS
Emission PM (g/kW.h)
Emission CO (g/kW.h)
Emission HCNOx (g/kWh)
Emission HC (g/kW.h)
N/A
N/A
N/A
N/A
EXHAUST
Exhaust gas temperature (°C)
Exhaust gas flow (kg/m)
Max. exhaust back pressure (mm EC)
475
26
750
FUEL
Consumption @ 110% load (L/h)
Consumption @ 100% load (L/h)
Consumption @ 75% load (L/h)
Consumption @ 50% load (L/h)
71
66
50
35
OIL
Oil capacity (L)
Min. oil pressure (bar)
Max. oil pressure (bar)
Oil consumption 100% load (g/kWH)
Carter oil capacity (L)
30-36
1
5
0.3
N/A
HEAT BALANCE
Heat rejection to exhaust (kW)
Radiated heat to ambiant (kW)
Haet rejection to coolant (kW)
207
25
105+50
AIR INTAKE
Max. intake restriction (mm EC)
Intake air flow (kg/m)
625
25